230V - 12V/50-3
|
230V - 24V/60-3
|
Communication & monitoring
|
|
|
Communication interfaces
|
MasterBus, CZone, NMEA
|
MasterBus, CZone, NMEA
|
General
|
|
|
Nominal output voltage
|
12 V
|
24 V
|
Max. output current primary output
|
50 A
|
60 A
|
Total charge current
|
50 A at 14,25 V
|
12 or 24 V
|
Max. AC current (230 V / 120 V)
|
3,5 A / 7,1 A
|
5-10 A at 12 V; 5-20 A at 24 V (adjustable)
|
Number of battery outlets
|
3 (max.)
|
max. 20 A at 24 V
|
Battery bank size
|
200-400 Ah
|
60 A at 28.8 V
|
Nominal input voltage
|
120/240 V (80-275 V) 50/60 Hz
|
120/230 V (80-275 V) 50/60 Hz
|
Power supply mode
|
yes
|
yes
|
Galvanic isolation
|
yes
|
yes
|
Display/read-out
|
LED display
|
LED display
|
Dimensions, hxwxd
|
291 x 210 x 105 mm 11.5 x 8.3 x 4.1 inch
|
384 x 250 x 127 mm 15.1 x 9.8 x 5.0 inch
|
Weight
|
2.5 kg (5.5 lb)
|
5.9 kg (13.0 lb)
|
Compliance
|
CE, CEC, DOE, ABYC, UL1236, cULus, SAE J1171, ISO 8846, ACMA
|
CE, ABYC, UL1236, SAE J1171, ISO 8846, CEC/DOE, RCM/C-Tick, RMRS, RRR
|
Technical specifications
|
|
|
Charge characteristic
|
IUoUo, automatic / 3-step+ for Gel/AGM/flooded/Lithium Ion + user defined option
|
IUoUo, automatic / 3-step+ for Gel/AGM/flooded/Lithium Ion + user defined option
|
Temperature compensation
|
-30 mV/°C / -38 mV/°F; incl. temperature sensor
|
-60 mV/°C / -76 mV/°F; incl. temperature sensor
|
DC voltage compensation
|
through automatic compensation or MasterShunt
|
through automatic compensation or MasterShunt
|
Power consumption (DC side)
|
< 2 mA (MasterBus off)
|
< 2 mA (MasterBus off)
|
Current Control function
|
yes, through MasterBus or CZone
|
yes, through MasterBus or CZone
|
Power factor control
|
> 0,98
|
> 0.98
|
Temperature range (ambient temp.)
|
-25 °C to 70°C, derating > 40 °C
|
-25 °C to 80 °C, derating < 0 °C and > 40
|
Cooling
|
vario fan
|
vario fan
|
Protection degree
|
IP23, vertical mounting
|
IP23, vertical mounting
|
Protections
|
over-temperature, overload, short circuit, high/low battery voltage, ignition protection
|
over-temperature, overload, short circuit, high/low battery voltage, ignition protection
|
Charger Status Interface (alarm contact)
|
yes, using a Multipurpose Contact Output (code 77030500)
|
yes, using a Multipurpose Contact Output (code 77030500)
|